Setting up [DI Branch]
Select the Destination unit. To set up based on the information inputted to DI.
- In the Edit Flow window, Tap [DI Branch].
The ProcItem Setting window is displayed.
- In the "Item tab" area, tap [Setting].
- In the "Input branch setting" area, tap the DI input from the Input List for which the destination of the branch is to be set up.
"DI Input" (input signal) for the selected unit is displayed in "DI input".
- Tap [] for "Destination unit", and select the destination unit.
Tapping [
] will allow you to see the current Scene Unit list.
Important
- If the unit No. after [DI Branch] is not selected at destination, the repeated measurement may occur.
Note - The judgement result for a processing unit and the overall judgement are determined respectively at the following times.
- When the measurement of the processing unit is executed
- When the measurements of all processing units are completed
The processing unit that is not measured by branching is also cleared when the measurements of all units are completed.
- Repeat the Steps 3 to 4 and set up the branching units for other input.
Note - Up to 32 (0 to 31) units can be set up in destination.
- The time when the "Input branch" is executed is the time when the controller is actuated by the DI signal.
- Tap [OK].
After confirmation, the ProcItem Setting window will be closed.
- Perform measurement test.
- Verify measurement results.
When NG is displayed, please measure again and make Adjust if necessary.
Important
- To indicate the end of the branching end, please ensure to set up "End" right after the last unit at Destination.
End