When Using Measurement Results Externally (DI Branch)

Value Available in Expression

When this processing unit is selected in the "Unit" area of the Setting Expression window, the measurement items available in expressions are displayed in the sub-menu.
The items and contents displayed in the sub-menu are shown in the following table.
For how to set up expression, see Structure and Creation of Expression.
Table: Values Available in Expression (DI Branch)
Measurement items
Character string
Description
Judge
JG
Judgement result
DI input
DI
DI input No. (00000 to 11111)
Destination Unit No.
BU
Destination No.

External Reference List

The data types and their numbers that are available to refer from other processing units and external devices are shown below. For the input method, see "Input Format" in the User's Manual, "How To Connect & Communicate With External Devices".
Table: External Reference List (DI Branch)
No.
Data Name
Set/Get
Data Range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
DI input No.
Get only
No. used to indicate the DI input (00000 to 11111)
6
Unit No. at Destination
Get only
Unit No. at Destination (-1: End processing, 0 to 32767: unit No.)
120 to 151
Destination Unit No. 0 to
Destination Unit No. 31
Set/Get
-1: End processing
0 to 9999: unit No.