[Output Parameter (Scan Edge Width)]

Specify how to treat the coordinates to be output to the external devices as measurement results.
Important
  • If you change an output parameter after setting judgement condition, measurement result changes. When you change an output parameter, reset judgement condition as well.
  1. In the "Item tab" area, tap [Output parameter].
  2. Specify a value for each item.
    Output Parameter - Detail Area
    Table: Setting Values for Output Parameters
    Setting Item
    Set Value
    [Factory default]
    Description
    Output coordinates
    • [After scroll]
    • Before scroll
    Select which coordinate values should be output to the external device as measurement results, values before scroll or values after scroll.
    Calibration
    • [OFF]
    • ON
    Select which coordinate values should be output to the external device as measurement results, values converted to the actual dimension (Calibration: ON) or values in the camera image (Calibration: OFF).
    Reflect to overall Judgement
    • [ON]
    • OFF
    Select whether to reflect the judgement result of this processing unit to the overall judgement of the scene.
    • Selecting [ON] reflects the judgement result of this processing unit on the overall judgement of the scene.
    • Selecting [OFF] does not reflect the judgement result of this processing unit on the overall judgement of the scene.
Note
For the subsequent operations, see Setting Up [Scan Edge Width].