[Output Parameter (Character Inspection)]

Specify how to treat the coordinates to be output to the external devices as measurement results.
Important
  • After setting up the measurement parameters, changing the output parameters will cause measurement results to vary accordingly. If the output parameters have been changed, re-specify the measurement parameters, too.
  1. In the "Item tab" area, tap [Output parameter].
  2. Specify a value for each item.
    Output Parameter - Detail Area
    Table: Setting Values for Output Parameters
    Setting Item
    Set Value
    [Factory default]
    Description
    Reflect to overall judgement
    • [ON]
    • OFF
    Specify whether to reflect the judgement result of this processing unit to the overall judgement of the scene.
    • Selecting [ON] will reflect the judgement result of this processing unit on the overall judgement of the scene.
    • Selecting [OFF] will not reflect the judgement result of this processing unit on the overall judgement of the scene.
    Character output
    Character output
    • [Unchecked]
      (Not output)
    • Checked
      (Output)
    Specify whether to output measurement result strings to an external device.
    Output device
    • [RS-232C/RS-422]
    • Ethernet
    When "Character output" is checked (Output), this specifies the device to which strings are output.
Note
  • The overall judgement result of the scene is output to the OR signal to be sent via the parallel interface. Also, it is displayed in the "Measurement information display" area in the upper part of the Main screen.
  • Output characters are encoded in ASCII code. This means that other characters than alphanumerical characters and symbols will not be output correctly.
For the subsequent operations, see Setting up [Character Inspection].