[Output Parameter (Character Inspection)]
Specify how to treat the coordinates to be output to the external devices as measurement results.
Important
- After setting up the measurement parameters, changing the output parameters will cause measurement results to vary accordingly. If the output parameters have been changed, re-specify the measurement parameters, too.
- In the "Item tab" area, tap [Output parameter].
- Specify a value for each item.
Table:
Setting Values for Output Parameters
|
Set Value [Factory default]
|
|
Reflect to overall judgement
|
|
Specify whether to reflect the judgement result of this processing unit to the overall judgement of the scene.
- Selecting [ON] will reflect the judgement result of this processing unit on the overall judgement of the scene.
- Selecting [OFF] will not reflect the judgement result of this processing unit on the overall judgement of the scene.
|
|
|
- [Unchecked]
(Not output)
- Checked
(Output)
|
Specify whether to output measurement result strings to an external device.
|
|
- [RS-232C/RS-422]
- Ethernet
|
When "Character output" is checked (Output), this specifies the device to which strings are output.
|
Note - The overall judgement result of the scene is output to the OR signal to be sent via the parallel interface. Also, it is displayed in the "Measurement information display" area in the upper part of the Main screen.
- Output characters are encoded in ASCII code. This means that other characters than alphanumerical characters and symbols will not be output correctly.