Points on Measurement Test and Adjustment (Character Inspection)
In addition to the camera-input image, the registered model and the detection coordinates (the cross-shaped cursor) will also be displayed in the "Image display" area.
Table:
Text Displayed (Character Inspection)
|
|
|
|
OK / unmeasured: Black NG: Red
|
|
|
|
The following strings are displayed. The larger numbers have priority. 0: OK 1: Correlation value NG 2: Character count NG 4: Verification NG
|
|
When the NG Cause is the character count NG: Red Other NGs: Black
|
The number of measured characters is displayed.
|
|
When the NG Cause is verification NG: Red Other NGs: Black
|
A character string read from the target unit is displayed.
|
|
When the NG Cause for each character is the correlation value NG: Red Other NGs: Black
|
The correlation values for each character are displayed. Example) When 0123 is read Correlation values: 0(99) 1(56) 2(80) 3(27)
|
Points on Adjustment
Select the adjustment method referring to the following points.
When the processing speed is slow:
- Reduce the measurement region size in [Region Setting].
When the judgement is NG (insufficient memory):
- Reduce the measurement region size in [Region Setting].