User's Manual
Environment Setting Part
>
Chapter 11 - Appendixes
> FAQ
FAQ
When Starting Up
POWER LCD not lit
Is power supply connected correctly?
Too low supply voltage (DC24V+10%,-15%)?
Monitor views nothing
Is monitor ON?
Is monitor cable connected correctly?
Does monitor have any failure?
Is power capacity enough (LCD)?
Have you performed "Power off LCD"? If you have, the monitor will recover if you tap on the bottom of the monitor.
Confused monitor images
Have power supply and cable generated electric noise?
Is monitor cable connected correctly?
Can not input
Are the cables of input devices (mouse, etc) connected correctly?
Is Angle too big in the case of Touch pen?
Camera image is not displayed, or image is blurred
Is lens cover open?
Is camera cable connected correctly?
Is lens diaphragm the biggest or smallest?
Is camera's shutter speed correct?
Is lighting method correct?
During Operation
Measurement results not viewed on monitor
Are windows other than the Main screen (the Edit Flow window, etc) displayed?
Is any setting window open?
A setting window means a window that opens separately such as the Edit Flow window and the Scene Maintenance window.
The touch screen responses slowly
Is it necessary to tap the touch screen continuously and quickly? If yes, the response to operation will become slower.
"NG (Insufficient memory)" is displayed in the "Detail result" area
Does a number of a certain processing item, such as Camera Image Input, exceed the limit?
Creating a New Scene
Image mode cannot be changed
Is the "Detail result" area active?
Listing Measurement Results
About Parallel Interface
Trigger signal (input) not accepted
Are cables connected correctly?
Signal cable disconnected?
You can check the communication status in the Communication Check window.
Checking the Communication Status (Parallel Interface)
Are the windows other than the Main screen (the Edit Flow window, etc) displayed?
Is any setting window open?
A setting window means a window that opens separately such as the Edit Flow window and the Scene Maintenance window.
Signals cannot be output to external devices
Is trigger signal input?
Are cables connected correctly?
Signal cable disconnected?
You can check the communication status in the Communication Check window.
Checking the Communication Status (Parallel Interface)
Were the test and measurement performed or not?
Signal cannot be output to external devices during testing measurement.
About Serial Interface (RS-232C/422)
No communication available
Are cables connected correctly?
Does communication specification of external devices comply with controller?
You can check the communication status in the Communication Check window.
Checking the Communication Status (Serial Interface)
No response from controller after a period of operation
Is buffer memory of PC fully filled?
Please verify if data are correctly received according to current settings.
Data cannot be Saved
Does communication specification of external devices comply with controller?
Is "Flow Control" in communication specification set to "None"?
To save data, set "Flow control" to "OFF".
Setting Communication Specifications (Serial Interface)