Setting up [Parallel Data Out]

Note
Operations of the ProcItem Setting window
  1. In the Edit Flow window, tap [Parallel Data Out].
    The ProcItem Setting window is displayed.
  2. In the "Item tab" area, tap [Setting] and set up the output contents.
  3. In the "Item tab" area, tap [Output format] and select [Format] in the "Output setting" area.
    Output format - Output setting area
    Table: Output format (Parallel data)
    Set Value
    [Factory defaults]
    Description
    Binary
    Data are outputted in the binary form of 2's complement.
    For 2's complement, see User's Manual, "Terminology".
    BCD
    Data are outputted with 4 digits representing 1 decimal and 16 digits representing the sign and 3-place integers.
    • 15 to 12 digits
      Sign. (positive: 0000, negative: 1111)
    • 11 to 0 digits
      With 4 digits representing 1 decimal, a value that has the digits position of 10 to the 6th power can be represented (27 to 24 digits: the 7th digits position) to - (3 to 0 digits: the first digits position)
  4. Tap [OK].
    After confirmation, the ProcItem Setting window will be closed.
  5. In the "Control" area, check "Output" in [Test measurement setting] to enable the external output, and execute measurement.
  6. Verify measurement results.
    When NG is displayed, please verify measurement results and make Adjust if necessary.