When Using Measurement Results Externally (Fine Matching)

Value Available in Expression

When this processing unit is selected in the "Unit" area of the Setting Expression window, the measurement items available in expressions are displayed in the sub-menu.
The measurement items displayed in the sub-menu are explained below.
For how to set up expression, see Structure and Creation of Expression.
Table: Values Available in Expression (Fine Matching)
Measurement items
Character string
Description
Judge
JG
Judgement result
Quantity
DA
Number of labels
Area
AR
Area
Position X
X
X Coordinate of gravity position of measurement defects
Position Y
Y
Y Coordinate of gravity position of measurement defects

External Reference List

The data types and their numbers that are available to refer from other processing units and external devices are shown below. For the input method, see "Input Format" in the User's Manual, "How To Connect & Communicate With External Devices".
Table: External Reference List (Fine Matching)
No.
Data Name
Set/Get
Data Range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Number of labels
Get only
0 to 9999
6
Area
Get only
0 to 999999999.9999
7
Position X
Get only
-99999.9999 to 99999.9999
8
Position Y
Get only
-99999.9999 to 99999.9999
101
Output coordinates
Set/Get
0: After scroll
1: Before scroll
102
Calibration
Set/Get
0: OFF, 1: ON
103
Reflect in to overall judgement
Set/Get
0: ON, 1: OFF
120
Boundary inspection
Set/Get
0: OFF, 1: ON
121
Edge level
Set/Get
0 to 9
122
Normalization
Set/Get
0: OFF
1: ON
123
Perturbation
Set/Get
0: OFF
1: ON
124
Difference
Set/Get
0 to 255
125
Detection method
Set/Get
0: Binary
1: Labeling
126
Label No.
Set/Get
0 to 2499
127
Sort condition
Set/Get
0: area descending order
1: area ascending order
2: X descending
3: X ascending
4: Y descending
5: Y ascending
128
Upper limit of Labeling condition
Set/Get
0 to 999999999.9999
129
Lower limit of Labeling condition
Set/Get
0 to 999999999.9999
130
Upper limit of Quantity
Set/Get
0 to 9999
131
Lower limit of Quantity
Set/Get
0 to 9999
132
Upper limit of Area
Set/Get
0 to 999999999.9999
133
Lower limit of Area
Set/Get
0 to 999999999.9999
134
Upper limit of defect X-Coordinate
Set/Get
-99999.9999 to 99999.9999
135
Lower limit of defect Coordinate-X
Set/Get
-99999.9999 to 99999.9999
136
Upper limit of defect Coordinate-Y
Set/Get
-99999.9999 to 99999.9999
137
Lower limit of defect Coordinate-Y
Set/Get
-99999.9999 to 99999.9999