Points on Measurement Test and Adjustment (Defect)
In addition to the camera image, the measurement region will also be displayed in the "Image display" area.
Table:
Defect - Text Displayed (Defect)
|
|
|
|
|
|
|
X Coordinate of measurement defect position
|
|
Y Coordinate of measurement defect position
|
|
The measured maximum defect area
|
|
The gravity center X coordinates of the measured maximum defect area
|
|
The gravity center Y coordinates of the measured maximum defect area
|
Points on Adjustment
Please choose your adjustment methods as follows.
When the processing speed is slower
Perform the following settings in [Measurement].
- Set up [Defect Size] to a larger value.
- Reduce the difference between the upper and lower limits of [Defect Size].
when performing defect detecting on noise
- Set up [Defect judgement] in [Judgement condition] to a larger value.