Points on Measurement Test and Adjustment (Flexible search)

In addition to the camera image, the model and the search coordinates (the cross-shaped cursor) will also be displayed in the "Image display" area.
In the "Detail result" area on the Main screen, you can confirm the following contents in text.
User's Manual, "Displaying Flow and Detail Result"
Table: Text Displayed (Flexible Search)
Item
Description
Judge
Judgement result
Model No.
Model No. with the largest correlation value
Correlation
Correlation
Measured coordinate X
X coordinate of the position where the model is detected
Measured coordinate Y
Y coordinate of the position where the model is detected
Angle
Angle of the position where the model is detected

Points on Adjustment

Please choose your Adjust methods as follows.
When search fails (searching other positions)
To improve the search accuracy, the following Adjust should be made to [Measurement].
When the processing speed is slower
In addition, adjust other options in the "Model parameter" area of [Model].
Points on Adjustment
When the judgement is NG (insufficient memory)
Reduce the amount of information necessary for measurements by making the following adjustment in the "Model parameter" area of [Model].
  • Set "Stab." or "Skipping angle" to a value closer to the factory default.
  • Specify a smaller value for "Prec.".
Note
  • If lowering "Stab." leads to slower processing, it is likely that many candidates have been detected. In this case, specify a larger value for "Candidate LV" or "Stab."