Measurement Parameters (Fine Matching)

This item specifies the judgement conditions for measurement conditions and measurement results.
  1. In the Item Tab area, tap [Measurement].
  2. Select "Inspection" in the "Measurement condition" area.
    Measurement - "Measurement condition" area
    Setting item
    Set value
    [Factory default]
    Description
    Inspection
    Images that are different from the model will be converted into binary images internally."Inspection" that is used to detect binary images should be selected.
    [Binary area]
    Defect is judged based on the total area of white pixels.
    Description of binary area
    Labeling
    A white pixel will be detected as 1 label, which is then compared with a label which is consistent with the set conditions to determine whether or not it is a defect.
    Description of labeling
    If "Binary area" is selected, the following operations are not necessary.
    When Labeling is selected, the following items are set.
    Item
    Set value
    [Factory default]
    Description
    Label No.
    0 to 2499
    [0]
    Specify the label number used to determine whether defects exist.
    Different settings for "Sort condition" will lead to different number assignment.
    Sort condition
    Specify the conditions by which label number is re-assigned.
    When sorting referencing the X and Y coordinates, the upper left is the origin.This will not affect the coordinate systems set up through the [Camera Image Input] calibration.
    Illustration of sort conditions
    Area ascending
    Number re-assigning begins from the labels with smaller areas.
    Sort condition-Area ascending
    [Area descending]
    Number re-assigning begins from labels with larger area.
    X ascending
    Number re-assigning begins from the label with a smaller gravity X coordinate.
    Sort condition -X ascending
    X descending
    Number re-assigning begins from the label with a larger gravity X coordinate.
    Y ascending
    Number re-assigning begins from the label with a smaller gravity Y coordinate.
    Sort condition- Y ascending
    Y descending
    Number re-assigning begins from the label with a larger gravity Y coordinate.
    Label area
    [0] to [999999999]
    Specify the range of the area to be judged as a label.
  3. When the setting has been changed, tap [Measurement] in the Detail area to verify whether measurements can be made correctly.
    Measurement - "Detail" area
  4. Set up the judgement condition.
    Measurement - "Judgement condition" area
    Setting item
    Set value
    Description
    Quantity
    0 to 9999
    Specify the range of the number of labels that is judged to be OK..
    When "Binary area" is used, the white pixels as a whole will be regarded as one label.
    Area
    0 to 999999999.9999
    Specify the range of the area that is judged to be OK..
    When the "Labeling" is used, the area of the label number will be specified instead.
    Defect pos X
    -99999.9999 to 99999.9999
    Specify the X and Y axis move ranges for the center of gravity positions that are judged to be OK.
    When the "Labeling" is used, the center of gravity position of the label number will be specified instead.
    Defect pos Y
    -99999.9999 to 99999.9999
    Specify the X and Y axis move ranges for the center of gravity positions that are judged to be OK.
    When the "Labeling" is used, the center of gravity position of the label number will be specified instead.
    Note
    • Defect coordinates give the center of gravity position of detected defects.