Key Points for Test Measurement and Adjustment (Trend Monitor)

The following content can be confirmed in the "Detail result" area using text.
Displayed items
Description
Judge
Judgement result
Measurement
Latest measured value
Max
Max. measurement value during recording period
Min
Min. measurement value during recording period
Standard deviation
Standard deviation for measurement values during recording period
Plus 3σ
Average of measurement values during period recorded + standard deviation of the measurement values x 3
Plus σ
Average of measurement values during period recorded + standard deviation of the measurement values
Average
Average value for measurement values during recording period
Minus σ
Average of measurement values during period recorded - standard deviation of the measurement values
Minus 3σ
Average of measurement values during period recorded - standard deviation of the measurement values x 3
Measurement count
Measure count since the beginning of measurement
OK count
Number of measurements since starting to make measurements - NG count in number of measurements
NG count
Number of NG occurrences within the measurement count
Warning count
Warning count within the measurement count
Yield
OK count in number of measurements / Number of measurements since starting to make measurements