2D Code+

No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
6
Decoded character count
Get only
Number of characters included in code detected
7
Decoded character string
Get only
Character string included in code detected
8
Index
Get only
0 to (INDEX_NUM_MAX - 1)
-1: Where there was no match with any of the index comparison strings,or the index comparison string has not been set up.
9
Integrated quality
Get only
0 to 4
10
Contrast
Get only
0 to 4
11
Modulation
Get only
0 to 4
12
Fixed pattern damage
Get only
0 to 4
13
Decode
Get only
0 to 4
14
Axis non-uniformity
Get only
0 to 4
15
Grid non-uniformity
Get only
0 to 4
16
Correction of error not used
Get only
0 to 4
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120
Code type
Set/Get
0:Data Matrix ECC 200
1:QRcode
121
Flag used for special character judgement
Set/Get
0: '*"? are considered to be wild cards
1: '*"? are considered to be character strings
122
Flag used for special character classification
Set/Get
0: '*"? are considered to be wild cards
1: '*"? are considered to be character strings
123
Flag showing character string display results
Set/Get
0 : Not displayed
1 : Displayed
124
Character string display color
Set/Get
0: Black
1 : White
2: Red
3: Green
4: Blue
125
Character string display size
Set/Get
10 to 200
134
Code color setting
Set/Get
0: Black code
1 : White code
170
Upper limit of number of characters detected
Set/Get
0 to CHAR_NUM_MAX
171
Lower limit of number of characters detected
Set/Get
0 to CHAR_NUM_MAX
172
Judgement comparison character string
Set/Get
Comparison string used for judgement
173
Lower limit of overall quality
Set/Get
0 to 4
190
Grade overall quality display
Set/Get
0 : Not displayed
1 : Displayed
191
Grade: Contrast display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
192
Grade: Modulation display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
193
Grade: Fixed pattern damage display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
194
Grade: Decode display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
195
Grade: Axis non-uniformity display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
196
Grade: Grid non-uniformity display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
197
Grade: Correction of error not used display setting (DataMatrix, QR)
Set/Get
0 : Not displayed
1 : Displayed
300 to 335
Classification comparison character string
Set/Get
Verification string used for classification
400
Character output flag
Set/Get
0: Not output
1 : Output
401
Output device
Set/Get
0: RS-232C
1: Ethernet
402
Error output
Set/Get
Error output flag
403
Error message
Set/Get
Message output while outputting an error