Barcode+

No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
6
Decoded character count
Get only
0 to (CHAR_NUM_MAX - 1)
7
Decoded character string
Get only
0 to (CHAR_NUM_MAX - 1) characters
8
Index
Get only
0 to (INDEX_NUM_MAX - 1)
-1: Where there was no match with any of the index comparison strings,or the index comparison string has not been set up.
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120
Code type
Set/Get
0: JAN/EAN - 8
1: JAN/EAN - 8 Add - On 2
2: JAN/EAN - 8 Add - On 5
3: JAN/EAN - 13
4: JAN/EAN - 13 Add - On 2
5: JAN/EAN - 13 Add - On 5
6: UPC-A
7: UPC-A Add-On 2
8: UPC-A Add-On 5
9: UPC-E
10: UPC-E Add-On 2
11: UPC-E Add-On 5
12: Code 39
13: Code 93
14: Code 128
15: IFT (Interleaved 2 of 5)
16: Codabar (NW-7)
17: GS1 Databar (RSS-14)
18: GS1 Databar (RSS Lim.)
19: GS1 Databar (RSS Exp.)
121
Flag used for special character judgement
Set/Get
0: '*"? are considered to be wild cards
1: '*"? are considered to be character strings
122
Flag used for special character classification
Set/Get
0: '*"? are considered to be wild cards
1: '*"? are considered to be character strings
123
Flag showing character string display results
Set/Get
Flag regarding whether or not character string is displayed
124
Character string display color
Set/Get
0: Black
1 : White
2: Red
3: Green
4: Blue
125
Character string display size
Set/Get
10 to 100
133
Wide bar size
Set/Get
4 to 60.0
134
Narrow bar size
Set/Get
1.5 to 10.0
136
Check digit
Set/Get
0: Check digit is not used
1: Check digit is used
137
Number of characters detected setting
Set/Get
CHAR_NUM_MIN to CHAR_NUM_MAX
162
Upper limit of number of characters detected
Set/Get
0 to CHAR_NUM_MAX
163
Lower limit of number of characters detected
Set/Get
0 to CHAR_NUM_MAX
164
Judgement comparison character string
Set/Get
Comparison string used for judgement
300 to 335
Classification comparison character string
Set/Get
Verification string used for classification
400
Character output flag
Set/Get
0: Not output
1 : Output
401
Output device
Set/Get
0: RS-232C
1: Ethernet
402
Error output
Set/Get
Error output flag
403
Error message
Set/Get
Message output while outputting an error