Precise Defect

No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (not yet measured)
1: Judgement result OK
-1: Judgement result NG
5
Defect
Get only
0 to 999999999.9999
6
Position X
Get only
0 to 999999999.9999
7
Position Y
Get only
0 to 999999999.9999
8
Area
Get only
0 to 999999999.9999
9
Gravity X
Get only
0 to 999999999.9999
10
Gravity Y
Get only
0 to 999999999.9999
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120
Size X
Set/Get
4 to 64
121
Size Y
Set/Get
4 to 64
122
Sampling interval X
Set/Get
1 to 64
123
Sampling interval Y
Set/Get
1 to 64
124
Comparing interval X
Set/Get
1 to 32
125
Comparing interval Y
Set/Get
1 to 32
126
Detection object color
(for monochrome cameras only)
Set/Get
0: Both white/black
1: White
2: Black
127
Defect detection direction X
Set/Get
0: OFF
1: ON
128
Defect detection direction Y
Set/Get
0: OFF
1: ON
129
Inclined defect detection direction
Set/Get
0: OFF
1: ON
130
Defect judgement value
Set/Get
0 to 999
131
Area measurement
Set/Get
0: OFF
1: ON
132
Area meas, LV
Set/Get
0 to 999
133
Area judgement
Set/Get
0 to 999999999.9999
134
Profile display
Set/Get
0: OFF
1: ON
135
Element display
Set/Get
0: OFF
1: ON