Measurement Results for Which Output Is Possible (Trend Monitor)

The following values can be output using processing items related to results output.It is also possible to reference measurement values from expressions and other processing units.
Measurement items
Character string
Description
Judge
JG
Judgement result
Measurement
DT
Latest measured value
Warning
WN
Existence of warning occurrence
Maximum
MX
Max. measurement value during recording period
Minimum
MN
Min. measurement value during recording period
Deviation
DV
Standard deviation for measurement values during recording period
Plus 3σ
AP3
Average of measurement values during period recorded + standard deviation of the measurement values x 3
Plus σ
AP1
Average of measurement values during period recorded + standard deviation of the measurement values
Average
AV
Average value for measurement values during recording period
Minus σ
AM1
Average of measurement values during period recorded - standard deviation of the measurement values
Minus 3σ
AM3
Average of measurement values during period recorded - standard deviation of the measurement values x 3
Measurement count
MC
Measure count since the beginning of measurement
OK count
OC
Number of measurements since starting to make measurements - NG count in number of measurements
NG count
NC
Number of NG occurrences within the measurement count
Warning count
WC
Warning count within the measurement count
Yield
YD
OK count in number of measurements / Number of measurements since starting to make measurements