Key Points for Test Measurement and Adjustment (Scan Edge Widths)
The following contents can be displayed as text in the "Detail result" area.
|  |  | 
|---|
|  |  | 
|  | The maximum value of edge width | 
|  | The minimum value of edge width | 
|  | The average value of all the edge width | 
|  | The number of the scanned areas for which the detection of width failed | 
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
|  |  | 
|---|
|  | If the color of the edges to be detected is decided, specify the color with [Edge color].If results are not stable even with the color specified, specify a larger value for the color variance range. | 
| If noise is detected as an edge, specify larger values for "Noise level" and "Noise width". |