Key Points for Test Measurement and Adjustment (Model Dictionary)
The following content is displayed in the "Detail result" area as text.
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
| |
---|
| If the model image consists of detailed figures, specify a larger value for "Stab.". |
When "With rotation" is selected, if the model shape is complex, uncheck the "Smart mode" option. |
| If images that should be judged OK vary greatly, specify a smaller value for "Candidate LV". |
When the processing speed is slow
| |
---|
| If the model image is a simple figure or a large figure, specify a smaller value for "Stab."If lowering stability does not speed up processing, it is likely that many candidates have been detected. Raise the "Candidate LV" in [Measurement]. |
When "With rotation" is selected, if the model shape is simple, place a check at the "Smart mode" option. |
| If images that should be judged OK vary little, specify a larger value for "Candidate LV". |