Output Parameters (Area Gravity Center)

Specify how to treat the coordinates to be output to the external device as measurement results.This item can be changed if necessary.Normally, the factory default value will be used.
Important
  • After setting up the measurement parameters, changing the output parameters will cause measurement results to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
  1. Tap [Output parameter] in the "Item tab" area.
  2. Specify each of the following items.
    Output parameter - "Detail" area
    Setting item
    Set value
    [Factory default]
    Description
    Output Coordinates
    • [After scroll]
    • Before executing position compensation
    As measurement results, select whether to output coordinate values to external devices before or after the position deflection correction is applied.
    Calibration
    • [OFF]
    • ON
    Select whether to reflect the calibration in the values output to the external device as measurement results.
    ON: Output the coordinates converted into actual dimensions.
    OFF: Output the camera coordinate values.
    Reflect to overall judgement
    • [ON]
    • OFF
    Enables choosing whether or not the judgement result of this processing unit is reflected in the scene overall judgement.