Reference Position (Area Gravity Center)
When the measurement region is set, the center of gravity is automatically set at the same time as the reference position.This item is used to change the reference position to any desired position.This is handy for measuring the positional deviation from a certain position.In the same way for the reference area, when the region settings are made, they are set automatically based on the measurement region.
- In the "Item tab" area, tap [Ref. position].
In the "Image display" area, the current reference position will be displayed as the crosshair cursor.
- Tap the position to be set as the reference position.
Note - If necessary, finely adjust with numeric input and the arrow buttons.
- If necessary, in the "Display setting" area, set up display settings for the images displayed in the "Image display" area.
For color cameras:
Setting item | Set value [factory default] | Description |
---|
Extract image | | If you place a check at this option, images set with color specification are displayed. |
For monochrome cameras:
Setting item | Set value [factory default] | Description |
---|
Binary image | | The image is displayed in binary with black and white. |