Key Points for Test Measurement and Adjustment (Defects/Contamination)
In the "Detail result" area on the Main screen, you can confirm the following contents in text.
| |
---|
| |
| |
| X Coordinate of measured defect position |
| Y coordinate of measured defect position |
| The measured maximum defect area |
| Center of gravity X coordinate of the measured maximum defect area |
| Center of gravity Y coordinate of the measured maximum defect area |
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
Noise is detected as defects.
| |
---|
| Specify a larger value for "Defect judgement" in the judgement conditions. |
Judgement will be NG.
| |
---|
| Make the measurement region larger than the lower limit of the defect size.Or make the lower limit of the defect detection size smaller than the measurement region. |
When the processing speed is slow
| |
---|
| Specify a larger value for the "Defect size". |
Reduce the difference between the upper and lower limits of "Defect size". |