Logging Conditions (Image Logging)

Indicate the image to perform logging for.If 4 cameras are connected, image logging is performed for 4 cameras each time.
  1. Tap [Logging conditions] in the item tab area.
  2. Set the logging conditions.
    Logging Conditions - "Detail" area
    Setting item
    Set value
    [Factory default]
    Description
    Logging condition
    • [None]
    No images are saved.
    • Only NG
    Saves images only if an NG occurs.If an NG occurs downstream from the image logging processing unit, image logging is not performed. Insert image logging as close to the end of the scene as possible
    • All
    All measured images are saved.
  3. When "Only NG" is selected, tap [...].
    The Setting Expression window is displayed.
  4. Logging conditions are set using an expression.
  5. After setting up the expression, tap [OK].
    The expression is confirmed.
  6. Set up the judgement upper limit and the judgement lower limit for "Judgement".
    Logging Conditions - "Detail" area
    Setting item
    Set value
    [Factory default]
    Description
    Judgment condition
    -999999999.9999
    to
    999999999.9999
    This is a judgement condition for the expression. Set upper and lower limits for judging as OK.