Inspecting and Measuring

Search

No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Correlation value
Get only
0 to 100
6
Measure X
Get only
-99999.9999 to 99999.9999
7
Measure Y
Get only
-99999.9999 to 99999.9999
8
Measure angle
Get only
-180 to 180
9
Reference
Get only
-99999.9999 to 99999.9999
10
Reference
Get only
-99999.9999 to 99999.9999
11
Reference angle
Get only
-180 to 180
12
Detected coordinate X
Get only
-99999.9999 to 99999.9999
13
Detected coordinate Y
Get only
-99999.9999 to 99999.9999
14
Count
Get only
0 to 32
101
Output Coordinates
Set/Get
0: After scroll
1: Before scroll
102
Calibration
Set/Get
0: OFF
1:ON
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120
Search mode
Set/Get
0: Correlation
1: Shape
121
With rotation
Set/Get
0: OFF
1: ON
122
Upper limit of the rotation angle
Set/Get
-180 to 180
123
Lower limit of the rotation angle
Set/Get
-180 to 180
124
Skipping angle
Set/Get
1 to 30
125
Smart mode
Set/Get
0: OFF
1: ON
126
Stab. (CR)
Set/Get
1 to 15
127
Prec.
Set/Get
1 to 3
128
Stab. (PT)
Set/Get
1 to 5
129
Reference
Set/Get
0 to 99999.9999
130
Reference
Set/Get
0 to 99999.9999
132
Detection point X
Set/Get
0 to 99999.9999
133
Detection point Y
Set/Get
0 to 99999.9999
134
Sub-pixel
Set/Get
0: OFF
1: ON
135
Candidate Point Level
Set/Get
0 to 100
136
Upper limit of measure X
Set/Get
-99999.9999 to 99999.9999
137
Lower limit of measure X
Set/Get
-99999.9999 to 99999.9999
138
Upper limit of measure Y
Set/Get
-99999.9999 to 99999.9999
139
Lower limit of measure Y
Set/Get
-99999.9999 to 99999.9999
140
Upper limit of the angle
Set/Get
-180 to 180
141
Lower limit of the angle
Set/Get
-180 to 180
142
Corr. descending
Set/Get
0 to 100
143
Corr. descending
Set/Get
0 to 100
144
Disp model
Set/Get
0: OFF
1: ON
145
Detail candidate
Set/Get
0 to 100
146
Sort condition
Set/Get
0: Corr. ascending
1: Corr. descending
2: X ascending
3: X descending
4: Y ascending
5: Y descending
147
Search No.
Set/Get
0 to 31
148
Upper limit of count judgement
Set/Get
0 to 32
149
Lower limit of count judgement
Set/Get
0 to 32
150
Multiple output
Set/Get
0: OFF
1: ON
1000 + NN x 4
(NN = 0 to 31)
Correlation value
Get only
0 to 100
1001 + NN x 4
(NN = 0 to 31)
Measure X
Get only
-99999.9999 to 99999.9999
1002 + NN x 4
(NN = 0 to 31)
Measure Y
Get only
-99999.9999 to 99999.9999
1003 + NN x 4
(NN = 0 to 31)
Measure angle
Get only
-180 to 180