Sensitive Search

No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
1
Correlation value
Get only
0 to 100
2
Deviation
Get only
For color cameras: 0.000 to 219.9705
For monochrome cameras: 0.000 to 127.000
3
Measure X
Get only
-99999.9999 to 99999.9999
4
Measure Y
Get only
-99999.9999 to 99999.9999
5
Measure angle
Get only
-180 to 180
6
Detection point X
Get only
-99999.9999 to 99999.9999
7
Detection point Y
Get only
-99999.9999 to 99999.9999
8
Reference
Get only
-99999.9999 to 99999.9999
9
Reference
Get only
-99999.9999 to 99999.9999
10
Reference angle
Get only
-180 to 180
11
NG Sub-region
Get only
0 to 100
12
Sub-region Number
Get only
0 to 99
13
Sub-region Number(X)
Get only
0 to 9
14
Sub-region Number(Y)
Get only
0 to 9
15
Sub-region Pos. X
Get only
-99999.9999 to 99999.9999
16
Sub-region Pos. Y
Get only
-99999.9999 to 99999.9999
101
Output Coordinates
Set/Get
0: After scroll
1: Before scroll
102
Calibration
Set/Get
0: OFF
1:ON
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
121
With rotation
Set/Get
0: OFF
1: ON
122
Upper limit of the rotation angle
Set/Get
-180 to 180
123
Lower limit of the rotation angle
Set/Get
-180 to 180
124
Skipping angle
Set/Get
1 to 30
125
Smart mode
Set/Get
0: OFF
1: ON
126
Stab.
Set/Get
1 to 15
127
Prec.
Set/Get
1 to 3
129
Reference
Set/Get
0 to 9999
130
Reference
Set/Get
0 to 9999
132
Detection point X
Set/Get
0 to 9999
133
Detection point Y
Set/Get
0 to 9999
134
Sub-pixel
Set/Get
0: OFF
1: ON
135
Candidate Point Level
Set/Get
0 to 100
136
Upper limit of measure X
Set/Get
-99999.9999 to 99999.9999
137
Lower limit of measure X
Set/Get
-99999.9999 to 99999.9999
138
Upper limit of measure Y
Set/Get
-99999.9999 to 99999.9999
139
Lower limit of measure Y
Set/Get
-99999.9999 to 99999.9999
140
Upper limit of the angle
Set/Get
-180 to 180
141
Lower limit of the angle
Set/Get
-180 to 180
142
Corr. descending
Set/Get
0 to 100
143
Corr. descending
Set/Get
0 to 100
144
Disp model
Set/Get
0: OFF
1: ON
145
Upper limit of deviation
Set/Get
For color cameras: 0 to 221
For monochrome cameras: 0 to 127
146
Lower limit of deviation
Set/Get
For color cameras: 0 to 221
For monochrome cameras: 0 to 127
147
Upper limit of NG Sub-region
Set/Get
0 to 100
148
Lower limit of NG Sub-region
Set/Get
0 to 100
149
Sub-region stab.
Set/Get
1 to 15
150
Sub-region prec.
Set/Get
1 to 3
151
Sub-model number X
Set/Get
1 to 10
152
Sub-model number Y
Set/Get
1 to 10
153
Plain inspection
Set/Get
0: OFF
1: ON
154
NG Sub-region (155,156 setting/acquisition target)
Set/Get
0 to 99
155
Enabled/disabled of sub-region
Set/Get
0: Disabled
1: Enabled
156
Measurement type of sub-region
Set/Get
0: Search
1: ColorData
-1: No processing item
157
Display cursor (position)
Set/Get
0: OFF
1: ON
158
Display cursor (Sub-region Pos.)
Set/Get
0: OFF
1: ON
159
Sub-region margin
Set/Get
0 to 10
165
Disabled region retention flag
Set/Get
0: Not retained
1 : Retained
1000 + N
(N = 0 to 99)
Correlation value of sub-region
Get only
0 to 100
1100 + N
(N = 0 to 99)
Deviation of sub-region
Get only
For color cameras: 0.000 to 219.9705
For monochrome cameras: 0.000 to 127.000