Output Format (Parallel Data Output)

  1. In the Item Tab area, tap [Output format] and select [Format] in the output setting area.
    Output format - "Output setting" area
    Set value
    [factory default]
    Description
    [Binary]
    Data is output as 2's complement binary data.
    For 2's complement
    BCD
    Data is output expressing 1 digit with 4 bits and expressing 3-digit integers and signs with 16 bits.
    • 15 to 12 bits
      Sign. (positive: 0000, negative: 1111)
    • 11 to 0 bits
      Data is expressed with 1 digit for every 4 bits and is expressed from the hundreds place (bits 11 - 8: 3rd digit) to the ones place (bits 3 - 0: 1st digit).
  2. Tap [OK].