Key Points for Test Measurement and Adjustment (Color Data)
The following content can be confirmed in the "Detail result"area using text.
For color cameras
| |
---|
| |
| R (red) element average value |
| G (green) element average value |
| B (blue) element average value |
| The color difference between the average color and reference color in the measurement region |
| Color deviation in the measurement region |
For monochrome cameras
| |
---|
| |
| Difference between the average density and the reference density in the measurement region |
| Density deviation in the measurement region |
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
| Remedy |
---|
| For a color camera, place a check at [Normalization]. |
When the processing speed is slow
| |
---|
| Set the measurement region to be as small as possible. |