Measurement Parameters (Search)
Specify the search measurement conditions and the judgement conditions for the measurement results.
- In the Item Tab area, tap [Measurement].
- In the "Measurement condition" area, specify a value for each item.
| Set value [factory default] | |
---|
| | When a check is placed at sub-pixel, the position information can be measured in units of sub-pixels.However, this requires more processing time. |
| | Specify the threshold value with which to detect candidate points in a rough search.Specify a smaller value when model search results are unreliable. |
Setting item | Set value [factory default] | Description |
---|
| | Select to execute a multi search. |
Detail LV | 0 to 100 [75] | Specify the threshold value with which to detect candidate points in a detail search. |
Sort condition | - Corr. ascending
- [Corr. descending]
- X ascending
- X descending
- Y ascending
- Y descending
| Specify the conditions by which the search number is re-assigned. When sorting referencing the X and Y coordinates, the upper left is the origin. |
Search No. | 0 to 31 [0] | Input the search number for outputting the data. |
- When the setting has been changed, tap [Measurement] in the Detail area to verify whether measurements can be made correctly.
- Set up the judgement condition.
Note - The values beside each item are measurement results of the displayed image.Take these values into consideration to determine the upper and lower limits.
| | |
---|
Count | 0 to 32 | Specify the number of detections that are judged to be OK. |
| -99999.9999 to 99999.9999 | Specify the range of X-axis shifting that is judged to be OK. |
| -99999.9999 to 99999.9999 | Specify the range of Y-axis shifting that is judged to be OK. |
| | Specify the range of angles that are judged to be OK. |
| | Specify the range of correlation values that are judged to be OK.However, when the correlation value of the measurement result is 0, the judgement result will be NG regardless of the lower limit setting. |