Measurement Parameters (Focus)

Measurement parameters can be changed as needed to address unstable focus values.
  1. In the item tab area, tap [Measurement].
  2. In the "Display" area, tap [Change display] to switch between camera image types.
    (Re-measurement images are not shown on the setting window.)
    Measurement parameter - "Display" area
    Setting item
    Setting value
    Description
    ON
    Through
    The latest image is always input from the camera and displayed.
    Freeze
    The image that was scanned in the immediately preceding measurement is displayed.
  3. Set the focus value.
    The focus value is displayed chronologically in real time in the graph area.
    Measurement parameter - "Focus adjustment" area
  4. Set up the judgement condition.
    Measurement parameter - "Judgement condition" area
    Setting item
    Setting value
    [Factory default]
    Description
    Focus
    0.0000 to 255.0000
    [50.0000]
    This item specifies the judgement value for focus.