Measurement Parameters (Focus)
Measurement parameters can be changed as needed to address unstable focus values.
- In the item tab area, tap [Measurement].
- In the "Display" area, tap [Change display] to switch between camera image types.
(Re-measurement images are not shown on the setting window.)
Setting item | Setting value | Description |
---|
ON | Through | The latest image is always input from the camera and displayed. |
Freeze | The image that was scanned in the immediately preceding measurement is displayed. |
- Set the focus value.
The focus value is displayed chronologically in real time in the graph area.
- Set up the judgement condition.
Setting item | Setting value [Factory default] | Description |
---|
Focus | 0.0000 to 255.0000 [50.0000] | This item specifies the judgement value for focus. |