Filter Setting (Halation Cut+)

This item sets the filter.
  1. In the Item Tab area, tap [Filter Setting].
  2. In the "Display" area, tap [Change display] to switch between camera image types.
    Filter setting - "Display" area
    The displayed contents of the Image Display area will be switched.
    Setting item
    Set value
    [Factory default]
    Description
    Display
    Through image display
    The latest image is always input from the camera and displayed.
    [Freeze image display]
    The image that was scanned in the immediately preceding measurement is displayed.
  3. Set each item in the "Filter parameter" area.
    Filter setting - "Filter param" area
    Setting item
    Set value
    [Factory default]
    Description
    RGB ratio
    -100 to 100
    [0]
    Adjust the balance of the red brightness and blue brightness for the shot image.
    Specifying a larger value in the positive direction (R direction) makes the R component easier to suppress.
    Specifying a larger value in the negative direction (B direction) makes the B component easier to suppress.
    Gain
    0.0001 to 9.9999
    [1.0000]
    Adjust the gain for compensating the brightness of the output image.
  4. As necessary, check the image after conversion.
    Filter setting - "Filter param" area
    Setting item
    Set value
    [Factory default]
    Description
    Filtered image
    • [Checked]
    • Unchecked
    To display the original image, uncheck here.