Save Destination (Image Logging)

  1. Set the logging images save destination.
    Enabled when "Save to memory + file" is selected as the save destination in the system image logging settings.
    Save destination - "Destination" area
    Setting item
    Setting value
    [Factory default]
    Description
    Sub folder name
    -
    Designates sub folder names. Creates a sub folder in the save destination in system logging settings.
    The following characters cannot be used for designating a file name.
    \ / : * ? " < > |
    Prefix
    -
    Sets the prefix for the save file name.
    The set character string is added at the beginning of the name of the save file.
    If the system logging settings designate a prefix, the file name is set to [prefix designated by image logging] + [prefix designated by system logging settings] + image logging file name.
  2. Set the File count in folder, if necessary. (FZ3-9IconIcon/H9IconIcon only)
    Save Destination - "Write optimization" area
    Setting item
    Setting value
    [Factory default]
    Description
    File count in folder
    0 to 1000[200]
    Set the maximum number of files that can be saved in 1 folder.
    Reference
    • If too many files are saved in 1 folder, performance may drop. Performance drop can be prevented by setting [File count in folder].
    Important
    • If conditional branching is used, the number of files saved may vary from the specified number.
    • If the operation mode is [Single-line High-speed mode], images taken by odd-numbered measurements are stored in a file different from one containing images taken by even-numbered measurements.