Setting item | Set value [factory default] | Description |
---|---|---|
Candidate level | 30 to 100 [50] | Specify the threshold value with which to detect candidate points in a rough search. Specify a smaller value when model search results are unreliable. |
Sort condition |
| Set the sorting method for the measurement results. |
Search No. | [0] to 99 | Input the search number for outputting the data. |
Setting item | Set value [factory default] | Description | |
---|---|---|---|
Count | [1] to | Specify the number of targets to be detected. | |
[Fast] Normal Precise | This is set when measuring the position information in sub-pixel units. To emphasize precision, select [Precise].When [Precise] is selected, this requires more processing time. | ||
[0] to 100 | Specify the allowable overlapping range to be detected for detected images. 0: Do not allow overlapping - 100: Allow overlapping | ||
Search skipping Level | Auto |
| Specify how many pixels are skipped when performing a measurement of the measurement region. When automatic is selected, the search level is set automatically. |
Manual | [3] to 5 |
Setting item | Set value | Description |
---|---|---|
Count | 0 to 100 | Specify the number of detections to be judged as OK. |
Measure X | -99999.9999 to 99999.9999 | Specify the range of X-axis shifting that is judged to be OK. |
Measure Y | -99999.9999 to 99999.9999 | Specify the range of Y-axis shifting that is judged to be OK. |
Search angle | -180 to 180 | Specify the range of angles that are judged to be OK. |
Correlation | 0 to 100 | Specify the range of correlation values that are judged to be OK.However, when the correlation value of the measurement result is 0, the judgement result will be NG regardless of the lower limit setting. |