Upper Limits of Processing Item Parameters
For processing items where the upper limit value is changed based on the image size of the camera being used, the description of the upper limit value is expressed using "_MAX".Upper limit values for each camera are as follows.
| | For 0.3 megapixel cameras: | | For 5 megapixel cameras: |
---|
| The max value in the X-axis orientation | | | 2447 |
| The max value in the Y-axis orientation | | | 2043 |
| | 239 (straight line W = 319) | 599 (straight line W = 799) | 1021 (straight line W = 1223) |
| | 239 (circle/ellipse R1=319) | 599 (circle/ellipse R1=799) | 1021 (circle/ellipse R1 = 1223) |
| | (X_MAX+1) * (Y_MAX+1) = 307200 | (X_MAX+1) * (Y_MAX+1) = 1920000 | (X_MAX+1) * (Y_MAX+1) = 5003712 |
| Maximum number of lines that can be loaded | | | 2043 |