Back
Next
User's Manual
Environment Setting Section
>
External Reference Tables
>
Measurement
> Label Data
Label Data
No.
Data name
Set/Get
Data range
0
Judge
Get
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Label No.
Get
0 to 2499
6
Area
Get
0 to 999999999.9999
7
Gravity X
Get
-99999.9999 to 99999.9999
8
Gravity Y
Get
-99999.9999 to 99999.9999
101
Output Coordinates
Set/Get
0: After scroll
1: Before scroll
102
Calibration
Set/Get
0: OFF, 1: ON
103
Reflect to overall judgement
Set/Get
0: ON, 1: OFF
120
Label unit
Set/Get
None (-1) to 9999
121
Label No.
Set/Get
0 to 2499
122
Upper limit of the area
Set/Get
0 to 999999999.9999
123
Lower limit of the area
Set/Get
0 to 999999999.9999
124
Upper limit of gravity X
Set/Get
-99999.9999 to 99999.9999
125
Lower limit of gravity X
Set/Get
-99999.9999 to 99999.9999
126
Upper limit of gravity Y
Set/Get
-99999.9999 to 99999.9999
127
Lower limit of gravity Y
Set/Get
-99999.9999 to 99999.9999