No. | Data name | Set/Get | Data range |
---|---|---|---|
0 | Judge | Get only | 0: No judgement (unmeasured) 1: Judgement result OK -1: Judgement result NG |
1 | Correlation value | Get only | 0 to 100 |
2 | Deviation | Get only | For color cameras: 0.000 to 219.9705 For monochrome cameras: 0.000 to 127.000 |
3 | Measure X | Get only | -99999.9999 to 99999.9999 |
4 | Measure Y | Get only | -99999.9999 to 99999.9999 |
5 | Measure angle | Get only | -180 to 180 |
6 | Detection point X | Get only | -99999.9999 to 99999.9999 |
7 | Detection point Y | Get only | -99999.9999 to 99999.9999 |
8 | Reference X | Get only | -99999.9999 to 99999.9999 |
9 | Reference Y | Get only | -99999.9999 to 99999.9999 |
10 | Reference angle | Get only | -180 to 180 |
11 | NG Sub-region | Get only | 0 to 100 |
12 | Sub-region Number | Get only | 0 to 99 |
13 | Sub-region Number(X) | Get only | 0 to 9 |
14 | Sub-region Number(Y) | Get only | 0 to 9 |
15 | Sub-region Pos. X | Get only | -99999.9999 to 99999.9999 |
16 | Sub-region Pos. Y | Get only | -99999.9999 to 99999.9999 |
101 | Output Coordinates | Set/Get | 0: After scroll 1: Before scroll |
102 | Calibration | Set/Get | 0: OFF 1:ON |
103 | Reflect to overall judgement | Set/Get | 0: ON 1: OFF |
121 | With rotation | Set/Get | 0: OFF 1: ON |
122 | Upper limit of the rotation angle | Set/Get | -180 to 180 |
123 | Lower limit of the rotation angle | Set/Get | -180 to 180 |
124 | Skipping angle | Set/Get | 1 to 30 |
125 | Smart mode | Set/Get | 0: OFF 1: ON |
126 | Stab. | Set/Get | 1 to 15 |
127 | Prec. | Set/Get | 1 to 3 |
129 | Reference X | Set/Get | 0 to 9999 |
130 | Reference Y | Set/Get | 0 to 9999 |
132 | Detection point X | Set/Get | 0 to 9999 |
133 | Detection point Y | Set/Get | 0 to 9999 |
134 | Sub-pixel | Set/Get | 0: OFF 1: ON |
135 | Candidate Point Level | Set/Get | 0 to 100 |
136 | Upper limit of measure X | Set/Get | -99999.9999 to 99999.9999 |
137 | Lower limit of measure X | Set/Get | -99999.9999 to 99999.9999 |
138 | Upper limit of measure Y | Set/Get | -99999.9999 to 99999.9999 |
139 | Lower limit of measure Y | Set/Get | -99999.9999 to 99999.9999 |
140 | Upper limit of the angle | Set/Get | -180 to 180 |
141 | Lower limit of the angle | Set/Get | -180 to 180 |
142 | Upper limit of the corr. | Set/Get | 0 to 100 |
143 | Lower limit of the corr. | Set/Get | 0 to 100 |
144 | Save registered model | Set/Get | 0: OFF 1: ON |
145 | Upper limit of deviation | Set/Get | For color cameras: 0 to 221 For monochrome cameras: 0 to 127 |
146 | Lower limit of deviation | Set/Get | For color cameras: 0 to 221 For monochrome cameras: 0 to 127 |
147 | Upper limit of NG Sub-region | Set/Get | 0 to 100 |
148 | Lower limit of NG Sub-region | Set/Get | 0 to 100 |
149 | Sub-region stab. | Set/Get | 1 to 15 |
150 | Sub-region prec. | Set/Get | 1 to 3 |
151 | Sub-model number X | Set/Get | 1 to 10 |
152 | Sub-model number Y | Set/Get | 1 to 10 |
153 | Plain inspection | Set/Get | 0: OFF 1: ON |
154 | NG Sub-region (155,156 setting/acquisition target) | Set/Get | 0 to 99 |
155 | Enabled/disabled of sub-region | Set/Get | 0: Disabled 1: Enabled |
156 | Measurement type of sub-region | Set/Get | 0: Search 1: ColorData -1: No processing item |
157 | Display cursor (position) | Set/Get | 0: OFF 1: ON |
158 | Display cursor (Sub-region Pos.) | Set/Get | 0: OFF 1: ON |
159 | Sub-region margin | Set/Get | 0 to 10 |
165 | Disabled region retention flag | Set/Get | 0: Not retained 1 : Retained |
1000 + N (N = 0 to 99) | Correlation value of sub-region | Get only | 0 to 100 |
1100 + N (N = 0 to 99) | Deviation of sub-region | Get only | For color cameras: 0.000 to 219.9705 For monochrome cameras: 0.000 to 127.000 |