Setting Communication Specifications (Ethernet - Non-procedure)

Communication specifications such as communication speed and IP addresses are set for Ethernet communication.
Setting Communication Specifications (RS-232C/422 - Non-procedure)
Important
  • Use the same communication specification settings for the controller and the external device.
  • When making system settings/Ethernet settings, do not send external input into the Ethernet.
  1. On the Main screen, tap the [System] menu - [Communication] - [Serial] - [Ethernet].
    The Ethernet window is displayed.
  2. Set the following items.
    Ethernet window
    Setting item
    Set value
    [Factory default]
    Description
    Address setting
     
     
    • Obtain an IP address automatically
    • [Use the following IP address]
    Set the IP address of the controller.
    When "Obtain an IP address automatically" is selected, the IP address of the controller will be automatically obtained.
    When "Use the following IP address" is selected, set the IP address, subnet mask, and the default gateway address.
    IP address
    a.b.c.d
    a: 1 to 223
    b: 0 to 255
    c: 0 to 255
    d: 0 to 255
    [10.5.5.100]
    Input the controller IP address.
    Sub-net mask
    0.0.0.0 to 255.255.255.255
    [255.255.255.0]
    Input the subnet mask address.
    Default gateway address
    0.0.0.1 to 255.255.255.254
    [10.5.5.110]
    Input the default gateway address.
    DNS server
    a.b.c.d
    a: 1 to 223
    b: 0 to 255
    c: 0 to 255
    d: 0 to 255
    [10.5.5.1]
    Input the DNS server address.
    I/O setting
     
     
    Input mode
    [Normal]
    This item cannot be changed.
     
    Input format
    [ASCII]
    This item cannot be changed.
     
    Output IP address
    a.b.c.d
    a: 1 to 223
    b: 0 to 255
    c: 0 to 255
    d: 0 to 255
    [0.0.0.0]
    Input the output destination IP address.
     
    I/O port No.
    0 to 65535
    [9600]
    Set the port No. to use for data I/O with the controller.
  3. Tap [OK].
    The settings are confirmed and the Ethernet window closes.