Key Points for Test Measurement and Adjustment (Color Average and Deviation)

The following content can be confirmed in the "Detail result"area using text.
For color cameras
Displayed items
Description
Judge
Judgement result
R average
R (red) element average value
G average
G (green) element average value
B average
B (blue) element average value
Color difference
The color difference between the average color and reference color in the measurement region
Color deviation
Color deviation in the measurement region
For monochrome cameras
Displayed items
Description
Judge
Judgement result
Density average
Difference between the average density and the reference density in the measurement region
Deviation
Density deviation in the measurement region

Key Points for Adjustment

Select the adjustment method referring to the following points.
When the measurement results are unstable
Parameter to be adjusted
 
Measurement parameter
For a color camera, place a check at [Normalization].
When the processing speed is slow
Parameter to be adjusted
Remedy
Region setting
Set the measurement region to be as small as possible.