When Using Measurement Results Externally (ECM Search)

The following values can be output using processing items related to results output.It is also possible to reference measurement values from expressions and other processing units.
Measurement items
Character string
Description
Judge
JG
Judgement result
Correlation value
CR
Correlation with the model
Measure X
X
X coordinate of the position where the model is detected
Measure Y
Y
Y coordinate of the position where the model is detected
Measure angle
TH
Angle of the position where the model is detected
Magnification MX
MX
X-axis magnification of the detected model
Magnification MY
MY
Y-axis magnification of the detected model
Reference X
SX
X coordinate of the reference position of the registered model
Reference Y
SY
Y coordinate of the reference position of the registered model
Reference angle
ST
Angle of the registered model
Detection point RX
RX
X coordinate of the registered model
Detection point RY
RY
Y coordinate of the registered model