Key Points for Test Measurement and Adjustment (Flexible Search)

The following content is displayed in the "Detail result" area as text.
Displayed items
Description
Judge
Judgement result
Model No.
Model No. of the biggest correlation
Correlation value
Correlation value
Measure X
X coordinate of the position where the model is detected
Measure Y
Y coordinate of the position where the model is detected
Angle θ
Angle of the position where the model is detected
Note
  • If the model is an ellipse, its circumscribing rectangle is displayed as the search result of the model.

Key Points for Adjustment

Select the adjustment method referring to the following points.
When the measurement results are unstable
Searching other positions
Parameter to be adjusted
Remedy
Model parameter
Specify a larger value for the "Prec."
If the measurement results are unstable only when "With rotation" is selected, specify a smaller value for the "Skipping angle".
When "With rotation" is selected, if the model shape is complex, uncheck the "Smart mode" option.
If the image has low contrast or blurred edges, set the "Search mode" to "CR".
If the model image consists of detailed figures, specify a larger value for "Stab."
Measurement parameter
If the precision is low, place a check at "Sub-pixel".
If images that should be judged OK vary greatly, specify a smaller value for "Candidate LV".
If the model image is small and unstable, specify a smaller value for the "Reduction".
The judgement is NG (insufficient memory)
Parameter to be adjusted
Remedy
Region setting
Make the search region as small as possible.
Model parameter
Bring "Stab." close to the factory default value.
Bring the "Skipping angle" close to the factory default value.
Specify a smaller value for "Prec.".
When the processing speed is slow
Parameter to be adjusted
Remedy
Region setting
Make the search region as small as possible.
Model Registration
Make the area to register as the model as small as possible.
Model parameter
If the model image is a simple figure or a large figure, specify a smaller value for "Stab."If lowering stability does not speed up processing, it is likely that many candidates have been detected. Raise the "Candidate LV" in [Measurement].
When "With rotation" is selected and the model image is a simple figure, specify a larger value for "Skipping angle".
When "With rotation" is selected and the model image is a simple figure, place a check at "Smart mode".
If the position precision is high, specify a smaller value for "Prec.".
If the rotation angle range is large, set the "Search mode" to "PT".
Measurement parameter
If images that should be judged OK vary little, specify a larger value for "Candidate LV".
If the position precision is high, uncheck "Sub-pixel".