Measurement Parameters (Flexible Search)

Specify the search measurement conditions and the judgement conditions for the measurement results.
  1. In the "Item tab" area, tap [Measurement].
  2. In the "Measurement condition" area, specify a value for each item.
    Measurement - "Measurement condition" area
    Setting item
    Set value
    [factory default]
    Description
    Sub-pixel
    • Checked
    • [Unchecked]
    When a check is placed at sub-pixel, the position information can be measured in units of sub-pixels.However, this requires more processing time.
    Candidate Point Level
    0 to 100
    [70]
    Specify the threshold value with which to detect candidate points in a rough search.Specify a smaller value when model search results are unreliable.
  3. When the setting has been changed, tap [Measure] in the "Detail" area to verify whether measurements can be made correctly.
    Measurement - "Detail" area
  4. Set up the judgement condition.
    Measurement - "Judgement condition" area
    Note
    • The values beside each item are measurement results of the displayed image.Take these values into consideration to determine the upper and lower limits.
    Setting item
    Set value
    Description
    Measure X
    -99999.9999 to 99999.9999
    Specify the range of X-axis shifting that is judged to be OK.
    Measure Y
    -99999.9999 to 99999.9999
    Specify the range of Y-axis shifting that is judged to be OK.
    Measure angle
    -180 to 180
    Specify the range of angles that are judged to be OK.
    Correlation value
    0 to 100
    Specify the range of correlation values that are judged to be OK.However, when the correlation value of the measurement result is 0, the judgement result will be NG regardless of the lower limit setting.