[Measurement (Classification)]
Set up the OK Judgement conditions based on the value in the model and the position (X, Y) to be found.
- In the "Item tab" area, tap [Measurement].
- In the "Measurement condition" area, specify a value for each item.
Table:
Measurement (Search)
|
Set Value [Factory Default]
|
|
|
|
Specify whether or not to perform measurement with sub-pixel interpolation. Sub-pixel processing achieves higher accuracy, but slows down measurement processing. For sub-pixels, see User's Manual, "Terminology".
|
|
|
Specify the threshold value used when detecting candidate points by a rough search. Specify a smaller value when model search results are unstable.
|
- When the setting has been changed, tap [Measure] in the "Detail" area to verify whether measurements can be made correctly.
- In the "Judgement condition" area, tap [...] and input a value for each item.
Note - The value beside each option are measurement results of the displayed image. Please determine the upper and lower limits based on these value.
Table:
Measurement (Classification) - Judgement Condition
|
Set Value [Factory Default]
|
|
|
|
-99999.9999 to [99999.9999]
|
Specify the range of X-axis shifting that is judged to be OK.
|
|
[-99999.9999] to 99999.9999
|
|
|
-99999.9999 to [99999.9999]
|
Specify the range of Y-axis shifting that is judged to be OK.
|
|
[-99999.9999] to 99999.9999
|
|
|
|
Specify the range of angles that are judged to be OK.
|
|
|
|
|
|
Specify the range of correlation values that are judged to be OK.
|
|
|