List of system data

Table: Data identification name 0
CameraControl
Camera delay setting
UdpNormal
Communication - Ethernet setting
SerialNormal
Communication - Serial setting
ParallelIO
Communication - Parallel setting
Configuration
Language setting/Startup setting
Logging
Logging setting
Measure
Measurement control setting
Table: Data identification name 1
CameraControl (Camera delay setting)
cameraDelay0
STEP-camera 0 delay
cameraDelay1
STEP-camera 1 delay
cameraDelay2
STEP-camera 2 delay
cameraDelay3
STEP-camera 3 delay
UdpNormal (Communication - Ethernet setting)
portNo
Port number
enableDhcp
Get an IP address automatically
0: OFF
1: ON
ipAddress
IP Address
subnetMask
Subnet mask
defaultGateway
Default gateway
destIpAddress
IP address to which the data is output
SerialNormal (Communication - Serial setting)
rsMode
Communication type
0: RS-232C
1: RS-422
baudRate
Baud rate (2400/4800/9600/19200/38400/576000/115200)
byteSize
Data length (7, 8)
parity
Parity
0: OFF
1: Odd
2: Even
stopBits
Stop bit (1, 2)
softFlow
Flow control
0: OFF
1: Xon/Xoff
delimiter
Delimiter
0: CR
1: LF
2: CR+L
timeout
Timeout
multiDrop
Multidrop
0: OFF
1: ON
mdUnitNo
Model number
broadcast
Broadcast under the multidrop connection
0: OFF
1: ON
ParallelIO (Communication - Parallel setting)
polarity
Output polarity
handshake
Output control
cycleTime
Output cycle
riseTime
Startup time
outputTime
Time to output
timeout
Timeout
delayCount
Delay count
orOutMode
One-shot OR signal
orOutputTime
One-shot OR signal time
Configuration (Language setting/Startup setting)
language
Language
jpn: Japanese mode
eng: English mode
InitialSceneNo
Startup scene number
initialSceneGroupNo
Startup scene group number
initialMeasureOut
Outputs the measurement result at startup
0: OFF
1: ON
Logging (Logging setting)
imageLogging
Image logging
0: Logging not executed
1: Logging only at NG
2: Logging all
dataLogging
Data Logging
0: Logging not executed
1: Logging only at NG
2: Logging all
imageLoggingDirectory
Destination folder to save image logging
dataLoggingDirectory
Destination folder to save data logging
imageLoggingPriority
Image logging mode
0: Logging operation has priority
1: Measurement interval has priority
imageLoggingScene
Switches the saving folder by image logging scene group/scene
0: Enable
1: Disable
imageLoggingJudge
Switches the saving folder by image logging overall judgement
0: Enable
1: Disable
imageLoggingHeader
String prepended to the image logging file name
Measure (measurement control setting)
stepError
STEP in measure
0: ERROR ON
1: ERROR OFF
sceneGroupSave
Save when switching a scene group
0: Save not performed when switching a scene group
1: Save performed when switching a scene group
captureDirectory
Directory in which a screen capture is saved